| Control channels per
control box |
6 |
| |
| Maximum current per
control channel |
16 |
Amperes | |
| Maximum total
current for box, 3 phase star connection |
3x32 |
Amperes | |
| Maximum total
current for box, single phase connection |
32 |
Amperes | |
| Temperature sensing
range on each channel |
0-200 |
Celsius | |
| Temperature
resulution of the system |
0.2 |
Celsius | |
| Control precision of
the system |
1 |
Celsius | |
| Number of possible
sensors to switch per control channel |
2 |
| |
| Number of possible
output cables per control channel |
2 |
| |
| Pulse width
modulation base time |
1 |
Second | |
| Pulse width
modulation increment time |
0.1 |
Second | |
| Method of
communication to the box |
Modbus TCP |
| |
| Communication baud
rate |
100 |
BaseT | |
| Temperature update
rate |
5 |
Seconds | |
| Maximum boxes on a
mould system |
20 |
Boxes | |
| Maximum input
voltage, 3 phase star connection |
480 |
Volts | |
| Minimum input
voltage, 3 phase star connection |
380 |
Volts | |
| Maximum input
voltage, single phase connection |
250 |
Volts | |
| Minimum input
voltage, single phase connection |
110 |
Volts | |